25kv 35kv XLPE Insulation 100% 133% Aia Armoured Mv90 Medium Voltage Cable Interlock Cables

Product Details
Customization: Available
Application: Underground, Power Station
Voltage: Low and Medium Voltage Cable
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (24)
Find Similar Products

Basic Info.

Model NO.
MV-90
Insulation Material
XLPE
Sheath Material
PE/PVC
Material Shape
Round Wire
Wire Core Material
Copper
Certification
CCC, CE
Model
Mv90
Brand
Jl
Rated Voltage
25kv,35kv
Number of Core
1
Refer Standard
Icea S-93-639 (NEMA Wc74)
Transport Package
Wooden Drum/Steel Drum
Specification
4AWG-1000MCM
Trademark
JL
Origin
Jiangsu, China
HS Code
8544492100
Production Capacity
2000km/Month

Product Description


Standards
National Fire Protection Standard (NEPA 70): National Electric Code AEIC CS8
ICEA S-93-639 (NEMA WC74), Standard for shielded power cable 5KV-46KV
ICEA S-97-682
IEEE 1202 - Flame Testing of cables for use in cable tray
ICEA T29-520 Vertical
UL 1072 for medium voltage cables.

Application
The three core cables are Designed for distribution of electrical power with nominal voltage Uo/ U ranging from 5KV to 46KV and frequency 50Hz. Three core cables are made of stranded copper or aluminium conductor, triple extruding insulating system consisting of thermosetting semi-conducting conductor shield, XLPE/TR-XLPE insulation and thermosetting semiconducting insulation shield. There are a number of designs of metallic shields including the copper tape helically applied with overlap, copper wire shield, concentric neutral, longitudinally applied corrugated copper tape and metal sheath available, which are surrounded with fillers and grounding conductor, overall binder tape and overall PVC, LSZH or PE jacket.

Construction

Conductors: Class B  stranded aluminium alloy 1350 or soft drawn annealed copper meeting the requirement of ASTM B3. 
Conductor Screen: extruded layer of semi-conducting crosslink compound
Insulation: cross-linked polyethylene compound (XLPE).Or High dielectric strength tree retardant XLPE (TR-XLPE)
Insulation Screen: semi-conducting crosslink compound
Metallic Screen:  copper tape screen
Separation Sheath: non-hygroscopic PVC or PP Tape.
Armour :Aluminum Interlocked Armor (AIA)
Over Sheath: PVC ,PE,LSZH Sheath

Technical data:
Operating Voltage:25KV,35KV
Operating Temperature: up to 90°C
Short Circuit Temperature( 5 seconds maximum duration ): 250°C

Parameter:

25kV 100% Three Conductor AIA
Conductor Insulation Thickness (mm/mils) Sheath Thickness (mm/mils) Overall Diameter (mm / in.) Cable Weight (kg/km / lbs/kft) Ampacity (Amps)
90°C In 90°C In Air
Duct
      (D) CU AL CU AL CU AL
1 AWG 6.60/260 3.56/140 63.5 2.5 4373 2939 3496 2350 170 135 185 145
1/0 AWG 6.60/260 3.56/140 65.8 2.59 4837 3251 3752 2522 195 150 215 170
2/0 AWG 6.60/260 3.56/140 68.1 2.68 5395 3626 4135 2779 220 170 245 190
3/0 AWG 6.60/260 3.56/140 71.6 2.82 6228 4186 4581 3079 250 195 285 220
4/0 AWG 6.60/260 3.56/140 74.9 2.95 7072 4753 5009 3367 285 220 325 255
250 MCM 6.60/260 3.56/140 77.7 3.06 7817 5254 5392 3624 310 245 360 280
350 MCM 6.60/260 3.56/140 83.8 3.3 9796 6584 6412 4310 375 295 435 345
500 MCM 6.60/260 3.56/140 90.9 3.58 12527 8420 7701 5176 450 355 535 425
750 MCM 6.60/260 3.56/140 102.1 4.02 17111 11501 9860 6627 545 440 670 540
25kV 133% Three Conductor AIA
1/0 AWG 8.76/345 3.56/140 76.2 3 5859 3938 4773 3208 195 150 215 170
2/0 AWG 8.76/345 3.56/140 78.5 3.09 6447 4333 5185 3485 220 170 245 190
3/0 AWG 8.76/345 3.56/140 81.3 3.2 7217 4851 5569 3743 250 195 285 220
4/0 AWG 8.76/345 3.56/140 84.8 3.34 8187 5503 6125 4117 285 220 325 255
250 MCM 8.76/345 3.56/140 87.9 3.46 8969 6028 6543 4398 310 245 360 280
350 MCM 8.76/345 3.56/140 93.5 3.68 10925 7343 7540 5068 375 295 435 345
500 MCM 8.76/345 3.56/140 101.3 3.99 13868 9321 9041 6077 450 355 535 425
                         
35kV 100% Three Conductor AIA
Conductor Insulation Thickness (mm/mils) Sheath Thickness (mm/mils) Overall Diameter (mm / in.) Cable Weight (kg/km / lbs/kft) Ampacity (Amps)
90°C In 90°C In
Duct Air
      (D) CU AL CU AL CU AL
1/0 AWG 8.76/345 3.56/140 76.2 3 5859 3938 4773 3208 195 150 215 170
2/0 AWG 8.76/345 3.56/140 78.5 3.09 6447 4333 5185 3485 220 170 245 190
3/0 AWG 8.76/345 3.56/140 81.3 3.2 7217 4851 5569 3743 250 195 285 220
4/0 AWG 8.76/345 3.56/140 84.8 3.34 8187 5503 6125 4117 285 220 325 255
250 MCM 8.76/345 3.56/140 87.9 3.46 8969 6028 6543 4398 310 245 360 280
350 MCM 8.76/345 3.56/140 93.5 3.68 10925 7343 7540 5068 375 295 435 345
500 MCM 8.76/345 3.56/140 101.3 3.99 13868 9321 9041 6077 450 150 535 170
35kV 133% t Three Conductor AIA
1/0 AWG 10.67/420 3.56/140 85.1 3.35 6865 4614 5779 3884 195 150 215 170
2/0 AWG 10.67/420 3.56/140 87.4 3.44 7479 5027 6218 4179 220 170 245 190
3/0 AWG 10.67/420 3.56/140 90.2 3.55 8280 5565 6631 4457 250 195 285 220
4/0 AWG 10.67/420 3.56/140 93.5 3.68 9192 6178 7128 4791 285 220 325 255
250 MCM 10.67/420 3.56/140 96.3 3.79 10000 6721 7574 5091 310 245 360 280
350 MCM 10.67/420 3.56/140 102.9 4.05 12146 8164 8762 5889 375 295 435 345
 

 