Customization: | Available |
---|---|
Application: | Underground, Power Station |
Voltage: | Low and Medium Voltage Cable |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
NA2XSERY Aluminum cables Power Transmission electric wire cable Application
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.
NA2XSERY Aluminum cables Power Transmission electric wire cable Construction
Conductor: Aluminium complying with IEC 60228 class 2.
Conductor Screen: extruded layer of semi-conducting crosslink compound
Insulation: Insulation is of polyvinyl chloride (PVC) intended for 1.8/3.6KV and 3.6/6KV cables, cross-linked polyethylene compound (XLPE)
Nom. Cross Section Area | Insulation Thickness at Nominal Voltage | |||||||
1.8/3KV | 3.6/6KV | 6/10KV | 8.7/15KV | 12/20KV | 18/30KV | 21/35KV | 26/35KV | |
(Um=3.6KV) | (Um=7.2KV) | (Um=12KV) | (Um=17.5KV) | (Um=24KV) | (Um=36KV) | (Um=42KV) | (Um=42KV) | |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm |
XLPE | XLPE | XLPE | XLPE | XLPE | XLPE | XLPE | XLPE | |
10 | 2 | 2.5 | - | - | - | - | - | - |
16 | 2 | 2.5 | 3.4 | - | - | - | - | - |
25 | 2 | 2.5 | 3.4 | 4.5 | - | - | - | - |
35 | 2 | 2.5 | 3.4 | 4.5 | 5.5 | - | - | - |
50 - 185 | 2 | 2.5 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
240 | 2 | 2.6 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
300 | 2 | 2.8 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
400 | 2 | 3 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
500 - 1600 | 2.2-2.8 | 3.2 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
Rated Voltage Uo/U | Operating Voltage (Um) | Testing Voltage (rms) |
6/10KV | 12KV | 25.5KV |
Nom. Cross-Section Area |
Steel Flat Wire Armoured Cables | Double Steel Tape Armoured Cables | ||||||||||
Nom. Bedding Thickness |
Armour Wire Size | Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
Nom. Bedding Thickness |
No of Steel Tapes x Nom Tape Thickness | Nom. Sheath Thickness |
Approx.Overall Diameter | Approx. Weight |
|||
CU | AL | CU | AL | |||||||||
mm2 | mm | mm | mm | mm | kg/km | mm | mm | mm | mm | kg/km | ||
50 | 1.9 | 0.8 | 3.3 | 80.5 | 9825 | 8986 | 1.9 | 2x0.5 | 3.5 | 82.5 | 9625 | 8786 |
70 | 2 | 0.8 | 3.6 | 85.5 | 11015 | 9769 | 2 | 2x0.8 | 3.8 | 87.6 | 10825 | 9569 |
95 | 2.1 | 0.8 | 3.8 | 88.5 | 12360 | 10580 | 2.1 | 2x0.8 | 3.9 | 90.5 | 12116 | 10327 |
120 | 2.1 | 0.8 | 3.9 | 91.5 | 13900 | 11715 | 2.1 | 2x0.8 | 4 | 94.5 | 13306 | 11110 |
150 | 2.1 | 0.8 | 4 | 94.8 | 15160 | 12440 | 2.1 | 2x0.8 | 4.1 | 97.5 | 14550 | 11830 |
185 | 2.2 | 0.8 | 4.1 | 99.5 | 17500 | 13450 | 2.2 | 2x0.8 | 4.2 | 101.7 | 16810 | 12765 |
240 | 2.3 | 0.8 | 4.2 | 104.1 | 19390 | 14890 | 2.3 | 2x0.8 | 4.4 | 107.5 | 18650 | 14150 |
300 | 2.4 | 0.8 | 4.4 | 109.5 | 21970 | 16280 | 2.4 | 2x0.8 | 4.6 | 112.8 | 21200 | 15500 |
400 | 2.5 | 0.8 | 4.6 | 116.3 | 25600 | 18430 | 2.5 | 2x0.8 | 4.8 | 118.8 | 24780 | 17600 |
Nom. Cross-Section Area |
Steel Flat Wire Armoured Cables | Double Steel Tape Armoured Cables | ||||||||||
Nom. Bedding Thickness |
Armour Wire Size | Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
Nom. Bedding Thickness |
No of Steel Tapes x Nom Tape Thickness | Nom. Sheath Thickness |
Approx.Overall Diameter | Approx. Weight |
|||
CU | AL | CU | AL | |||||||||
mm2 | mm | mm | mm | mm | kg/km | mm | mm | mm | mm | kg/km | ||
16 | 1.2 | 0.8 | 2.2 | 39.7 | 2795 | 2515 | 1.2 | 2x0.5 | 2.3 | 40.5 | 2680 | 2395 |
25 | 1.3 | 0.8 | 2.2 | 42.7 | 3305 | 2885 | 1.3 | 2x0.5 | 2.4 | 43.7 | 3195 | 2775 |
35 | 1.3 | 0.8 | 2.3 | 45.2 | 3835 | 3215 | 1.3 | 2x0.5 | 2.5 | 46.2 | 3720 | 3100 |
50 | 1.4 | 0.8 | 2.4 | 47.8 | 4325 | 3570 | 1.4 | 2x0.5 | 2.6 | 48.8 | 4200 | 3445 |
70 | 1.5 | 0.8 | 2.5 | 51.8 | 5320 | 4185 | 1.5 | 2x0.5 | 2.7 | 52.8 | 5185 | 4050 |
95 | 1.5 | 0.8 | 2.7 | 56.1 | 6450 | 4875 | 1.5 | 2x0.5 | 2.8 | 56.9 | 6280 | 4700 |
120 | 1.6 | 0.8 | 2.8 | 59.7 | 7545 | 5510 | 1.6 | 2x0.5 | 2.9 | 60.5 | 7360 | 5325 |
150 | 1.7 | 0.8 | 2.9 | 63.1 | 8610 | 6150 | 1.7 | 2x0.5 | 3 | 63.9 | 8420 | 5950 |
185 | 1.7 | 0.8 | 3 | 67.4 | 10120 | 6995 | 1.7 | 2x0.5 | 3.1 | 68.2 | 9910 | 6780 |
240 | 1.8 | 0.8 | 3.2 | 73 | 12430 | 8205 | 1.8 | 2x0.5 | 3.3 | 73.8 | 12200 | 7970 |
300 | 1.9 | 0.8 | 3.3 | 78.3 | 14775 | 9455 | 1.9 | 2x0.5 | 3.4 | 79.1 | 14530 | 9200 |
400 | 2 | 0.8 | 3.5 | 85.2 | 17950 | 11190 | 2 | 2x0.8 | 3.7 | 87.7 | 18600 | 11850 |
500 | 2.1 | 0.8 | 3.7 | 92.8 | 21970 | 13270 | 2.1 | 2x0.8 | 3.9 | 95.3 | 22680 | 13990 |
630 | 2.2 | 0.8 | 4 | 102.7 | 27480 | 16160 | 2.2 | 2x0.8 | 4.1 | 105 | 28200 | 16910 |
Nom. Cross- Section Area | D C Resistance CU / AL |
A C Resistance CU / AL |
Short Circuit Rating of Conductor CU / AL (1 sec) |
Capaci tance | Charging Current | Short Circuit Rating of Copper Wire Screen Per Core(1 sec) | Short Circuit Rating of Copper Tape Screen Per Core(1 sec) | Reactance | Inductance |
mm² | μΩ/m | μΩ/m | kA | pF/m | mA/m | kA | kA | μΩ/m | μΩ/m |
16 | 1150/1910 | 1470/2420 | 2.2/1.4 | 186 | 0.4 | 2.6 | 0.5 | 131 | 410 |
25 | 727/1200 | 927/1538 | 3.6/2.3 | 216 | 0.43 | 2.6 | 0.5 | 123 | 390 |
35 | 524/868 | 668/1113 | 5.0/3.2 | 237 | 0.47 | 2.6 | 0.6 | 115 | 370 |
50 | 387/641 | 494/822 | 6.8/4.4 | 266 | 0.52 | 2.6 | 0.6 | 109 | 350 |
70 | 268/443 | 343/568 | 9.8/6.3 | 298 | 0.6 | 2.6 | 0.7 | 103 | 330 |
95 | 193/320 | 248/410 | 13.3/8.5 | 334 | 0.67 | 2.6 | 0.7 | 99 | 320 |
120 | 153/253 | 196/325 | 17.2/11.0 | 365 | 0.73 | 2.6 | 0.8 | 96 | 310 |
150 | 124/206 | 159/265 | 21.2/13.5 | 392 | 0.78 | 4.3 | 0.8 | 93 | 300 |
185 | 99.1/164 | 128/211 | 26.6/17.0 | 430 | 0.86 | 4.3 | 0.9 | 90 | 290 |
240 | 75.4/125 | 98/161 | 34.9/22.3 | 476 | 0.95 | 4.3 | 0.9 | 87 | 280 |
300 | 60.1/100 | 80/130 | 43.8/28.0 | 524 | 1.05 | 4.3 | 1 | 85 | 270 |
400 | 47.0/77.8 | 64/102 | 57.3/36.6 | 580 | 1.16 | 5.8 | 1.1 | 81 | 260 |
500 | 36.6/60.5 | 51/81 | 72.3/46.2 | 630 | 1.26 | 5.8 | 1.2 | 78 | 250 |
630 | 28.3/46.9 | 42/64 | 91.2/58.3 | 690 | 1.36 | 5.8 | 1.3 | 76 | 240 |
1. Q: What types of cables do you offer?
A:We offer Ethernet, Fiber Optic, Power, Control, and Instrumentation cables.
2. Q: Are your cables compliant with industry standards?
A:Yes, all our cables meet international standards like IEC, ISO, and NEMA.
3. Q: How can I place an order?
A:Order through our website or contact our sales team for bulk orders.
4. Q: What is your lead time for delivery?
A: Standard delivery is 3-5 business days. Bulk orders may vary.
5. Q: Do you offer customization services?
A: Yes, we customize cables for specific project needs.
6. Q: What payment methods do you accept?
A:We accept credit/debit cards, bank transfers, and PayPal.
7. Q: What is your return policy? 30-day return policy for unused products.
A:Defective items must be reported within 7 days.
8. Q: How can I track my order? .
A:Use the tracking number in your shipping confirmation email.
9. Q: Do you offer technical support?
A:Yes, contact us via phone, email, or live chat.
10. Q: Are your cables suitable for outdoor use?
A:Yes, we offer weather-resistant and UV-resistant cables.
11. Q: Can I get a sample before placing a large order?
A:Yes, contact our sales team for samples.
12. Q: What is your warranty policy?
A:Standard 12-month warranty. Extended warranties available.
13. Q: How do I contact customer service?
A:E mail us
14. Q: Do you ship internationally?
A:Yes, contact us for shipping details.
15.Q: How do I request a quote for bulk orders?
A:Fill out the quote form on our website or contact our sales team.