This product is no longer promoted on Made-in-China.com. If you find any infringement or sensitive information of it, please contact us for handling. Thank you.

XLPE Insulated 3 Cores Mv Power Cables

Product Details
Application: Underground, Power Station
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Find Similar Products

Basic Info.

Model NO.
N2XSERY, N2XSEY
Insulation Material
XLPE
Sheath Material
PE/PVC
Material Shape
Round Wire
Wire Core Material
Cu or Al
Certification
CCC, CE
Model
N2xsery,N2xsey
Brand
Jl
Rated Voltage
1.8/3kv
Number of Core
1
Refer Standard
IEC 60502-1
Transport Package
Wooden Drum/Steel Drum
Specification
1.5-1000 Mm2
Trademark
JL
Origin
Jiangsu, China
HS Code
8544492100
Production Capacity
2000km/Month

Product Description


1.8/3kv Power Cables Three Cores Cables to IEC 60502 Standards

IEC 60502 Part 1(1.8/3KV)

1.8/3kv Power Cables Three Cores Cables to IEC 60502 Application
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

1.8/3kv Power Cables Three Cores Cables to IEC 60502 Construction

Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2. 
Conductor Screen: 
The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape.
Insulation: Insulation is of polyvinyl chloride (PVC) intended for 1.8/3.6KV and 3.6/6KV cables, cross-linked polyethylene compound (XLPE)

Nom. Cross Section Area Insulation Thickness at Nominal Voltage
1.8/3KV 3.6/6KV 6/10KV 8.7/15KV 12/20KV 18/30KV 21/35KV 26/35KV
(Um=3.6KV) (Um=7.2KV) (Um=12KV) (Um=17.5KV) (Um=24KV) (Um=36KV) (Um=42KV) (Um=42KV)
mm2 mm mm mm mm mm mm mm mm
  XLPE XLPE XLPE XLPE XLPE XLPE XLPE XLPE
10 2 2.5 - - - - - -
16 2 2.5 3.4 - - - - -
25 2 2.5 3.4 4.5 - - - -
35 2 2.5 3.4 4.5 5.5 - - -
50 - 185 2 2.5 3.4 4.5 5.5 8 9.3 10.5
240 2 2.6 3.4 4.5 5.5 8 9.3 10.5
300 2 2.8 3.4 4.5 5.5 8 9.3 10.5
400 2 3 3.4 4.5 5.5 8 9.3 10.5
500 - 1600  2.2-2.8  3.2 3.4 4.5 5.5 8 9.3 10.5
Insulaton Screen:   extruded layer of semi-conducting cross-link compound
Metallic Screen:Copper tape screen or copper wire with helically copper Tape
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene.
Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour .
Lapped Bedding : The lapped bedding consists of Polyester non woven fabrics .The thickness is1.5mm
Armour (for armoured cable):  It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour.
Outer Sheath: PVC, PE, HDPE, MDPE or LSZH

Installation and operation condition of cable
Operating Temperature: up to 70°C (PVC insulation); up to 90°C (XLPE or EPR insulation)
Temperature Range: -5°C ( PVC sheath ); -20°C ( PE sheath )
Short Circuit Temperature( 5 seconds maximum duration ): 140-160°C (PVC insulation);
250°C (XLPE)
Bending Radius: 12 x OD
Current Rating Conditions:
Ground Temperature:
20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W
Rated Voltage Uo/U Operating Voltage (Um) Testing Voltage
 (rms)
1.8/3KV 3.6KV 6.5KV  
 
1.8/3KV Power Cables Three Cores Cables to IEC 60502 Dimensional Data
Nom.Cross-Section Area   Unarmoured Cables Steel Wire Armoured Cables
Nom.Insulation Thickness Copper Tape Thickness Copper Wire Screen Area*  Nom.Sheath Thickness Approx.Overall Diameter Approx. Weight Nom.Bedding Thickness Armour Wire Size Nom.Sheath Thickness Approx. Overall Diameter Approx.
Weight
CU AL CU AL
mm2 mm mm mm2 mm mm kg/km mm mm mm mm kg/km
10 2 0.1 16 1.8 23 650 460 1.2 1.6 1.8 28 1480 1290
16 2 0.1 16 1.8 24 840 540 1.2 1.6 1.9 29 1720 1410
25 2 0.1 16 1.8 26 1160 680 1.2 1.6 1.9 32 2130 1650
35 2 0.1 16 1.8 29 1490 820 1.2 2 2.1 36 2810 2140
50 2 0.1 16 1.9 32 1900 1000 1.2 2 2.2 39 3340 2450
70 2 0.1 16 2 36 2580 1290 1.2 2 2.3 42 4200 2910
95 2 0.1 16 2.2 40 3440 1640 1.3 2.5 2.4 47 5620 3820
120 2 0.1 16 2.3 43 4220 1950 1.3 2.5 2.5 51 6580 4310
150 2 0.1 25 2.4 46 5090 2290 1.4 2.5 2.7 54 7680 4870
185 2 0.1 25 2.5 50 6240 2730 1.5 2.5 2.8 58 9060 5560
240 2 0.1 25 2.7 56 8030 3430 1.6 2.5 3 64 11200 6600
300 2 0.1 25 2.8 60 9890 4100 1.6 2.5 3.1 69 13590 7500
400 2 0.1 35 3.1 68 12530 5150 1.8 3.15 3.4 78 17260 9880
500 2.2 0.1 35 3.3 75.7 16680 7510 1.8 3.15 3.5 84.3 21780 13025
630 2.4 0.1 35 3.5 84.9 21770 10040 1.8 3.15 3.8 94.6 27400 16050
Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard.
Nom.Cross-Section Area Nom.Bedding Thickness Armour Wire Size Nom.Sheath Thickness Approx.Overall Diameter Approx.Weight Nom.Bedding Thickness No of Steel Tapes x Nom Tape Thickness  Nom.Sheath Thickness Approx. Overall Diameter Approx.
Weight
          CU AL         CU AL
mm2 mm mm mm mm kg/km mm mm mm mm kg/km
10 1.2 0.8 1.8 24.5 1245 1065 1.2 2 x 0.2 1.8 23.6 925 750
16 1.2 0.8 1.8 27.1 1565 1280 1.2 2 x 0.2 1.8 26.2 1205 925
25 1.2 0.8 1.8 29.7 1975 1525 1.2 2 x 0.2 1.9 29 1590 1145
35 1.2 0.8 1.9 32.5 2420 1805 1.2 2 x 0.2 1.9 31.6 1985 1370
50 1.2 0.8 2 35 2860 2080 1.2 2 x 0.2 2 34.1 2400 1605
70 1.2 0.8 2.1 38.7 3685 2525 1.2 2 x 0.5 2.2 39.5 3570 2410
95 1.3 0.8 2.2 42.9 4695 3080 1.3 2 x 0.5 2.3 43.7 4570 2950
120 1.3 0.8 2.3 46.4 5650 3585 1.3 2 x 0.5 2.4 46.1 5510 3440
150 1.4 0.8 2.4 49.6 6630 4085 1.4 2 x 0.5 2.6 50.6 6500 3955
185 1.5 0.8 2.6 54.1 7990 4820 1.5 2 x 0.5 2.7 54.9 7825 4650
240 1.6 0.8 2.7 59.2 10060 5790 1.6 2 x 0.5 2.8 60 9825 5600
300 1.6 0.8 2.9 64.6 12230 6865 1.6 2 x0.5 3 65.4 12030 6660
400 1.8 0.8 3.1 71 15200 8280 1.8 2 x 0.5 3.2 71.8 14970 8055
500 1.8 0.8 3.3 79.5 19090 10255 1.8 2 x 0.8 3.5 80.5 18880 10035
630 1.8 0.8 3.6 89.8 24400 12920 1.8 2 x 0.8 3.8 92.3 25070 13620

1.8/3KV Power Cables Three Cores Cables to IEC 60502 Electrical Data
Nom.Cross-Section Area D C Resistance
 CU / AL
A C Resistance
 CU / AL
Short Circuit Rating of Conductor
CU / AL
(1 sec)
Capacitance Charging Current Short Circuit Rating of Copper Wire Screen
(1 sec)
Short Circuit Rating of Copper Tape Screen
(1 sec)
Reactance Inductance Impedance
Trefoil Flat Trefoil Flat Trefoil Flat Spaced
Spaced Spaced cu AL cu AL
mm2 µΩ/m µΩm kA pF/m mA/m kA kA µΩ/m nH/m µΩ/ m µΩ/ m
10 1830/3080  2330/3920  1.4/0.9  160 0.25 2.6 0.4 101 390 23.6 925 750 3846 2332 3840
16 1150/1910  1460/2420  2.2/1.4  180 0.27 2.6 0.4 98 370 26.2 1205 925 2411 1478 2420
25 727/1200  929/1538  3.6/2.3  220 0.29 2.6 0.4 95 350 29 1590 1145 1544 952 1554
35 524/868  668/1113  5.0/3.2  250 0.31 2.6 0.5 92 330 31.6 1985 1370 1121 695 1131
50 387/641  494/822  6.8/4.4  270 0.33 2.6 0.5 88 310 34.1 2400 1605 834 527 844
70 268/443  343/568  9.8/6.3  310 0.35 2.6 0.6 84 290 39.5 3570 2410 583 386 597
95 193/320  248/410  13.3/8.5  350 0.38 2.6 0.6 81 270 43.7 4570 2950 427 300 446
120 153/253  196/325  17.2/11.0  380 0.46 2.6 0.7 79 250 46.1 5510 3440 345 257 367
150 124/206  159/265  21.2/13.5  420 0.5 2.6 0.7 77 260 50.6 6500 3955 287 229 313
185 99.1/164  128/211  26.6/17.0  460 0.56 2.6 0.8 76 250 54.9 7825 4650 237 206 267
240 75.4/125  98/161  34.9/22.3  510 0.61 4.3 0.9 74 240 60 9825 5600 191 185 226
300 60.1/100  80/130  43.8/28.0  570 0.68 4.3 1 73 250 65.4 12030 6660 163 174 203
400 47.0/77.8  64/102  57.3/36.6  590 0.7 5.8 1.1 71 240 71.8 14970 8055 141 164 184
500 36.6/60.5  57/81  72.3/46.2  610 0.72 5.8 1.2 69 230 80.5 18880 10035 124 158 171
630 28.3/46.9  42/64  91.2/58.3  630 0.74 5.8 1.3 67 220 92.3 25070 13620 110 151 160

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now